IP66 / IP67 // SEALED ALLOY HOUSING UNCOOLED LWIR + 4K CMOS

Sight that does not depend on light.

Thermal and visible imaging, single-spectrum and bispectral, fixed and motorised.

AUTONOMOUS EDGE ARCHITECTURE

We build the camera, and the part that watches it.

A thermal picture is only worth having if something is reading it at four in the morning. Detection, classification and change detection run on the camera, so a site with a thin link receives an alarm rather than a feed nobody watches.

Bispectral PTZ head
STANDARDIZED ARCHITECTURE

The range

Six configurations on one platform. Same housing, same control interface, same analytics.

  • AD-BPTZ FLAGSHIP
    Bispectrum PTZ Thermal and visible in one motorised head
  • AD-TPTZ THERMAL ONLY
    Thermal PTZ Single spectrum, motorised
  • AD-OPTZ VISIBLE ONLY
    Optical PTZ Visible and low light, non-thermal
  • AD-BFIX STATIC DUAL
    Bispectrum fixed Thermal and visible, static mount
  • AD-TFIX STATIC THERMAL
    Thermal fixed Single spectrum, static mount
  • AD-COMP COMPACT
    Compact thermal Small housing, short reach
QUESTIONS BUYERS ASK

Thermal cameras, answered

What does Access Dynamics make?

Thermal and bispectral cameras for industrial and enterprise sites: perimeters, plants, pipelines, ports, utilities and infrastructure. Six configurations share one platform, from a bispectral PTZ to a compact fixed thermal camera, with detection and analytics running on the camera itself.

Which camera configurations are available?

Bispectral PTZ (uncooled LWIR thermal plus 4K visible), thermal PTZ, optical PTZ, bispectral fixed, thermal fixed and compact thermal. Lenses and detector are chosen against the site and confirmed in writing with the quotation.

What does bispectral mean?

One housing carries two aligned channels: an uncooled long-wave infrared (LWIR) thermal sensor that sees heat in darkness, smoke and light fog, and a 4K CMOS visible camera for colour detail and identification. Both point at the same scene.

Which analytics run on the camera?

Change detection, intrusion and line crossing, classification of people, vehicles, vessels and animals, auto-tracking, hotspot and rate-of-rise alarms, occupancy and man-down, slew-to-cue from radar, and tamper and blockage detection.

Can it find hotspots on insulated pipework, conveyors and stockpiles?

Yes. Hotspot analytics combine an absolute temperature threshold, a rate-of-rise alarm and a comparison against the rest of the line, so an insulation anomaly on a hot line, a failing conveyor idler or a warming stockpile is flagged early. Areas expected to run hot, such as bare flanges, can be masked.

How does it connect to existing VMS, SCADA and alarm systems?

Video streams to standard video management software, events and control are available through an open API, Modbus TCP and OPC UA for SCADA and PLCs, and dry-contact alarm outputs drive sirens, lights and gates. An integration pack is available on request.

What environments is it built for?

A sealed IP66 / IP67 alloy housing with a salt-capable powder-coat finish, rated from −40 to +65 °C. Analytics run locally, with no cloud dependency.

Is surge protection included?

Yes. Each unit is supplied with compatible surge protection devices (SPDs) for its power, network and control lines.

How do I get a specification and quotation?

Send the specification request with the site, the targets and the distances that matter. The configuration, lenses and terms come back confirmed in writing with the quotation.

MODULAR PAYLOAD ARCHITECTURE

One platform, every configuration

Thermal or visible, one channel or two, motorised or fixed. Reach follows from the detector, the optics and the air between you and the target, so it is sized against your site and confirmed in writing.

Bispectral PTZ, three-quarter view
INTERACTIVE 3D CAD ENGINE • ACCELERATED CANVAS

Hardware Studio & Platform Configurator

Inspect precision-milled billet geometries, sensor payloads, and finish coatings in real-time 3D.

RASTERIZER: ACTIVE [60 FPS] • DRAG TO ORBIT • SCROLL TO ZOOM
VIEW PRESET:
1. SENSOR ARCHITECTURE
2. SHADING & INSPECTION MODE
3. HOUSING FINISH
CONFIGURED SYSTEM CODE:
AD-BPTZ-640-Z150-NGY-IP67
Bispectral Motorised 360° PTZ with Dual Thermal + Optical Channels, Naval Gray Powder Coat
JOHNSON CRITERIA / DRI

Optical Reach & Spatial Resolution Calculator

Calculate minimum detector line-pairs on critical human and vehicle targets across working ranges.

DETECTION (1.5 px) PROBABILITY 99.8% Critical human silhouette discerned against thermal clutter
RECOGNITION (6.0 px) PROBABILITY 94.2% Classification: Person vs. Quadruped vs. Light Vehicle
IDENTIFICATION (12.0 px) PROBABILITY 82.5% Positive ID: carried tools, high-visibility vest, vehicle type
OPTICAL FIELD-OF-VIEW CONE // JOHNSON CRITICAL DIMENSION

Horizontal field of view drawn from the aperture, with the detection, recognition and identification bands for a standing person. Each target is rasterised onto the detector at the selected distance, so the pixel and line-pair count is shown rather than asserted. Drag along the cone to set the range.

THERMAL FOCAL LENGTH
mm
VOx DETECTOR · 12 µm
HFOV × VFOV——
SWATH AT RANGE——
HUMAN · 1.8 × 0.5 m——
VEHICLE · 2.3 × 2.3 m——
CRITERIA ON Dc1.5 · 6 · 12 px0.75 · 3 · 6 line pairs
TARGET · Dc = √(W × H)DETECTION · 1.5 pxRECOGNITION · 6.0 pxIDENTIFICATION · 12.0 px

R = Dc · f / (n · p), where n is the pixel count across the critical dimension and p the 12 µm pitch; one line pair is two pixels. This is the geometric limit. Atmosphere, thermal contrast and NETD reduce it, which is why reach is sized against the site and confirmed in writing.

Motorised cameras

Continuous pan, tilt and zoom, for wide ground where one position has to cover several approaches.

Bispectrum PTZ

Thermal and visible in one motorised head

FLAGSHIP PTZ BISPECTRAL
Reach
ShortMidLong
Channels
LWIR + visible
Movement
360° continuous
Detector
Uncooled LWIR
Optics
Motorised zoom
Thermal PTZ

Single spectrum, motorised

PTZ SINGLE SPECTRUM
Reach
ShortMidLong
Channels
LWIR
Movement
360° continuous
Detector
Uncooled LWIR
Optics
Motorised zoom
Optical PTZ

Visible and low light, non-thermal

PTZ NON-THERMAL
Reach
ShortMidLong
Channels
Visible + low light
Movement
360° continuous
Detector
Low-light CMOS
Optics
Motorised zoom

Fixed cameras

One scene, watched without interruption. Less to specify, less to drive, and nothing that can be left pointing the wrong way.

Bispectrum fixed

Thermal and visible, static mount

FIXED BISPECTRAL
Reach
ShortMidLong
Channels
LWIR + visible
Movement
Fixed
Detector
Uncooled LWIR
Optics
Fixed focal
Thermal fixed

Single spectrum, static mount

FIXED SINGLE SPECTRUM
Reach
ShortMidLong
Channels
LWIR
Movement
Fixed
Detector
Uncooled LWIR
Optics
Fixed focal
Compact thermal

Small housing, short reach

FIXED COMPACT
Reach
ShortMidLong
Channels
LWIR
Movement
Fixed
Detector
Uncooled LWIR
Optics
Fixed focal
ENGINEERING STANDARDS

What every unit shares

One housing standard, one control interface, one analytics stack. An integrator learns the platform once.

Powder-coated housing and stainless handle
IP66 / IP67−40 to +65 °CSALT-CAPABLE FINISHCOMMON BOLT PATTERN
SECTION 01 // SENSORS

Detector and optics

Uncooled thermal, with a visible channel where the configuration calls for one. Optics are chosen against the target, not the other way round.

Thermal detectorUncooled VOx, VGA class and above, 12 µm
Thermal sensitivityNETD ≤ 50 mK @ f/1.0
Thermal opticsAthermalised, fixed or motorised, matched to the task
Visible channelLow-light CMOS, fixed or motorised zoom
SECTION 02 // ENCLOSURE

Housing and environment

One housing standard across the range: sealed, powder-coated, tested cold and tested hot, and finished for coastal air.

EnvironmentalIP66 / IP67, −40 to +65 °C, salt-capable finish
PowerDC or PoE, heater and de-ice on the motorised units
MountingPole, wall, mast and parapet, common bolt pattern
SECTION 03 // INTERFACES

Control and video

One control interface across the range, so an integrator learns the platform once and it holds for every unit on the site.

Pan and tilt360° continuous, −90° to +90°, preset ±0.1°
VideoH.265 / H.264 / MJPEG, triple stream
InterfacesRJ45 PoE++ or fibre, RS-485, alarm I/O
Surge protectionCompatible SPDs supplied for power, network and control lines
IntegrationONVIF Profile S and T, open API, Modbus TCP, OPC UA
ON-CAMERA NEURAL CLASSIFIER

Analytics that run on the camera

Rules are drawn on the scene, not written into a config file. Everything below works on the thermal channel alone, in full darkness.

Thermal aperture
EDGE INFERENCE CO-PROCESSOR // REAL-TIME SCENE PARSING [25 FPS]
SIMULATED HUD: CHANGE DETECTION
• SELECT ANY ANALYTICS MODULE BELOW TO STREAM LIVE TELEMETRY SIMULATION
ALGORITHM 01

Change detection

A learned reference frame, re-registered and drift-compensated, then differenced. Anything that appears, moves or disappears and stays that way raises an alarm.

ALGORITHM 02

Intrusion and line crossing

Zones and tripwires with direction, dwell and minimum-size filters.

ALGORITHM 03

Classification

Person, vehicle, vessel and animal, so a moving tree line stops calling the guard.

ALGORITHM 04

Auto-track

The head locks a target and holds it through the zoom range.

ALGORITHM 05

Hotspot and rate of rise

Absolute, rate-of-rise and line-comparison alarms on insulated pipework, conveyors, stockpiles, flares and forest.

ALGORITHM 06

Occupancy and man-down

People counted and posture watched in spaces where nobody should be alone.

ALGORITHM 07

Slew to cue

Radar, fence or a second camera puts a bearing in; the head is already looking.

ALGORITHM 08

Tamper and blockage

Alarms if the view is covered, the aim is knocked off or the focus is lost.

INTEROPERABILITY PROTOCOLS

It joins what you already run

A camera is delivered into a system that already exists. It speaks to that system rather than asking to replace it.

Head and pedestal
ONVIF PROFILE S • PROFILE T
VMS and ONVIF Profile S and T, appears as a camera in the system you already run
MODBUS TCP 502 • OPC UA 4840
SCADA and DCS Modbus TCP and OPC UA, so an alarm reaches the control room
RADAR COORD • PIDS PROTOCOL
Radar, fence and PIDS A bearing from any of them slews the head
REST JSON • RTSP 554 • WEBRTC
Open API and RTSP Direct control and stream access for your own software
DRY RELAY 24V 1A • OPTO-ISOLATED
Alarm contacts Dry contacts in and out for gates, lighting and sounders
MICROSDXC 512GB • ANR BACKFILL
Edge recording Local retention through a link outage, backfilled on recovery
SFP+ 1G/10G • IEEE 802.3BT • 4G/5G
Fibre, PoE and cellular Backhaul chosen to suit the run, not the other way round
IEEE 1588 PTP • NTP CLOCK
Time synchronisation NTP or PTP, so alarms from different systems line up
802.1X • TLS 1.3 • SECURE BOOT
Hardening No default credentials, certificate handling, ports closed by default
HOW IT CONNECTS · 14 s

From the mast to the systems you already run

Request the integration pack
INDUSTRIAL & ENTERPRISE DEPLOYMENTS

Where these cameras go

Dark, exposed, hot, or a long way from the nearest operator. Usually more than one of those at once.

Germanium window and shroud edge
Where it goes

Where it goes, and what it watches for

A visible camera needs light. A radar finds something without saying what it is. Thermal does both, in the dark — and the visible channel reads what needs reading. Detection runs on the camera, so a thin link carries alarms, not video.

Each detection shows its channel: thermal works in darkness and smoke, visible needs light, both uses the two together.

SECTOR 01

Industrial plant

Hot by design — where normal and dangerous sit a few degrees apart.

Process plant and refinery
Tank farms and bunds
Stockpiles and self-heating
Flare stacks and burners
Conveyors and transfer points
Furnaces, kilns and boilers
Substations and switchyards
Warehouse and battery storage
ON-CAMERA DETECTIONS

Hotspot and rate of rise

thermal

Threshold and rate-of-rise alarms on flares, stockpiles, bearings and switchgear — before it is a fire.

Flare and burner state

thermal

Flame on, flame out, pilot loss — read from heat, so smoke and glare do not confuse it.

Leak and spill signature

thermal

The thermal trace a release leaves on a bund floor or flange, before anything is visible.

Change detection

both

Anything that appears, moves or disappears from a static scene raises an alarm.

SECTOR 02

Perimeter and territory

Long, dark boundaries: did something cross, what was it, and which way did it go.

Border and buffer zones
Site perimeter and fence line
Critical assets and utilities
Ports, jetties and coastline
Airports and rail corridors
ON-CAMERA DETECTIONS

Intrusion and line crossing

thermal

Zones and tripwires with direction, dwell and size filters — through a moonless night.

Classification

thermal

Person, vehicle, vessel or animal, so a swaying tree line stops calling the guard.

Plate and vehicle identity

visible

Plate, make and colour at gates and access roads, where there is light to read by.

Slew to cue

both

Radar or a fence sensor sends a bearing; the head turns and holds the target.

SECTOR 03

Terrain and environment

Linear assets, watched from the one position there is.

Forest and wildfire watch
Pipeline right of way
Mining benches and haul roads
Landfill and waste heat
Canal and embankment
ON-CAMERA DETECTIONS

Third-party interference

thermal

Plant and people on a right of way where there should be neither.

Vehicle count and classification

both

Haul-road traffic and load cycles, counted and typed without ground loops.

Subsurface and waste-mass heat

thermal

Landfill and stockpile hotspots, mapped while still below the surface.

Wrong-way and speed

both

Direction and pace on haul roads, flagged against the rule for that stretch.

SECTOR 04

People and safety

Watching over people, rather than watching for them.

Confined space occupancy
Lone worker and man-down
Man overboard
Restricted zones during shutdown
ON-CAMERA DETECTIONS

Occupancy and man-down

thermal

Headcount and posture where nobody should be alone, or lying down.

Man overboard

thermal

A body-heat signature against cold water — where thermal has no rival.

PPE and compliance

visible

Helmet, hi-vis and harness checked at the gate and at height.

Queue and crowd density

both

Counts at muster points, gates and turnstiles — a number, not an opinion.

SECTOR 05

Forest, wildlife and conservation

Wide, empty ground where heat is the first warning and often the only one.

Forest and wildfire watch
Plantation and reserve boundary
Wildlife corridors
Protected-area approaches
ON-CAMERA DETECTIONS

Wildfire ignition

thermal

A heat source against cool canopy, found before a plume is visible.

Animal detection and classification

thermal

Large animals at a boundary, road or village edge — in darkness, without lights.

Human-wildlife conflict

thermal

People and animals resolved in one frame, so an approach is called early.

Unauthorised entry

thermal

Movement into a reserve at hours, or on lines, where there should be none.

LIFECYCLE SERVICE

After the crate is opened

The part of the job that decides whether the camera is still earning its place in year four.

Sealed power, network and control connectors
RJ45 PoE++ OR FIBRERS-485ALARM I/ODC OR POESPD SUPPLIED
IN THE BOX

Supplied with compatible surge protection

Every unit ships with surge protection devices (SPDs) matched to its interfaces, for fitting where each cable run enters the cabinet.

  • SPD · 01PowerDC or PoE supply line
  • SPD · 02NetworkRJ45 PoE++ data run
  • SPD · 03Control & alarm I/ORS-485 and dry-contact lines
ON-SITE COMMISSIONING
Commissioning Alignment, focus and analytics tuned on site against your scene
SPARES PROGRAMME
Spares Wipers, windows, seals and mounts held for the platform
COMPLETE TECHNICAL PACKAGE
Documentation Drawings, test records and the configuration file, with the unit
TERMS IN WRITING
Warranty Terms confirmed in writing with the quotation
DIRECT FACTORY SIZING

Tell us the job

The application, the distance, and what you need to make out at that distance. That is enough for a configuration and a price.

SITE PARAMETERS Sized against optical target distance
CONTACT & DELIVERY POINT

Opens your mail client with the answers filled in. Nothing leaves this page.

PRE-VALIDATION TELEMETRY

Factory Spec Sizing

Your requirements are sized against target geometry and atmospheric extinction coefficients.

PLATFORM BASE: AD-BPTZ-640
CALCULATED FOCAL: 75mm – 150mm Motorised
JOHNSON DRI ESTIMATE: D: 4.8km • R: 1.6km • I: 0.8km
ENCLOSURE SPEC: Milled 6061-T6 Billet • IP67
EST. DISPATCH: Confirmed with quotation
All configurations confirmed in engineering drawings prior to shipment.
Who we are

We would rather the camera did the talking.

Access Dynamics designs and builds thermal and bispectral imaging for sites that cannot afford to miss what happens in the dark. We keep a low profile. The work is for the people responsible for those sites, and we discuss it with them directly.

Bispectral PTZ head
PRINCIPLE 01 • NIGHT • SMOKE • GLARE
Built for the dark Every design decision starts from the conditions where a visible camera gives up — night, smoke, glare, distance.
PRINCIPLE 02 • ON-CAMERA INFERENCE
Decisions at the edge Detection runs on the camera itself, so the site gets an answer rather than another screen to watch.
PRINCIPLE 03 • SIX CONFIGURATIONS
One platform Six configurations, one housing standard, one control interface. An integrator learns it once.
ENQUIRIES IN CONFIDENCE

Enquiries are handled in confidence.

Tell us the site and the problem. We will tell you plainly whether we are the right answer.